Duet m106. This causes the fan to spin for even 1% usage.


Duet m106 There are significant configuration differences from version 2, so upgrading from RRF 2. Which bit do you think is contradictory?Assuming you have Duet WiFi or Duet Ethernet, normally you should connect the print fan to Fan0 and the hot end heatsink fan to Fan1. g still updates the value that is about to be restored using M106 R2 This solves the problem I have. x, using the I-1 parameter in the M106 command for a fan disables it, which frees up the pin for use as a general purpose I/O pin that can be controlled using M42. This is set with the L parameter above, to 20% in this example. 0001 is it hardware limited or is there a workaround for this? I would need this because I would like to control something other than a fan with the M106. Now the Extruder fan is often turnt off during printing and the part cooling fan is also not working very well. On the microSD card there are four different folders: gcodes, macros, sys and www. For example, on Duet 2 if you have a print running from SD card and logging enabled, you will be limited to a macro nesting depth of 8. Slicer is S3D. Feb 22, 2021 · If you are using a Duet 0. Currently the same set of recorded fan speeds is used for both pause/resume and tool change, but just as pause/resume and tool change record different sets of head coordinates that can be recalled using R1 or R2 respectively in G1 commands, so I may use different sets for Slicers will (optionally?) add G-code scripts to the beginning and end of their output file to perform specified actions before and/or after a print such as z-probing the build-area, heating/cooling the bed and hotend, performing ooze free "nozzle wipe" startup routine, switching system power on/off, and even "ejecting" parts. @britaliope, thanks for the report. What commands are you sending to adjust the PWM? According to the docs the FAN outputs on the Duex5 v0. It's usually well below 1%. The P1 works perfectly, Jan 25, 2019 · RepRapFirmware for Duet 2 WiFi/Ethernet FIRMWARE_VERSION: 2. The thermostatically controlled fan is also always on, even if the temperature is below 45C. Nov 23, 2019 · So for my example, in the header I use M452 P2 without the r255, still use the M106 p2 S0 to direct the output to 5v fan output, but I don't then need the M106 P2 S0. 400 Run May 6, 2021 · Thanks for sharing! I’ve got mine sorted now, and in the process of doing so, I found some things that RepRap Firmware 3. Scope This document is relevant to: all Duet boards Firmware versions: all firmware versions Introduction All Duet mainboards are able to monitor the MCU (microcontroller) and the stepper driver temperatures. 1 in the first feed move, but replace it with G1 X Y F S25 for a laser power of 25/255ths. I also tried changing the tool to the non zero fan to see if that was it. Is there a setting that I can change that will include the P value? M106: Fan On M107: Fan Off M108: Cancel Heating M109: Set Extruder Temperature and Wait M116: Wait M135: Set PID sample interval M140: Set Bed Temperature (Fast) or Configure Bed Heater M141: Set Chamber Temperature (Fast) or Configure Chamber Heater M143: Maximum heater temperature M144: Bed Standby M190: Wait for bed temperature to reach See User manual: Connecting and configuring fans and GCode M106 for more details. What commands are you sending to ad @dc42 said in Question about M106: The resolution depends on the PWM frequency you have set. 1 is for the hotend, which is controlled via M106 P0 and 2 for part cooling, which are controlled via M106 P1 and M106 P2. How would you be able to test the fans individually to make sure each fan is connected to the ri Mar 15, 2023 · Doubtful. It is just "accepting the command". For example, when you set the drive mapping so that you get 2 X drives and 2 Y drives, you can configure 2 endstops, (for example ^xstop+^e0stop) and homing X or Y will associate the 2 end stops with the 2 separate drives, so you don’t need to separate The Duet 3 Mainboard 6XD is designed to allow interfacing with the most common external stepper and servo motor drivers using step and direction signals, with support for 6 external drivers. 5 The fan has 2 cables and is for 24 volts I also attached the config. I have rewritten that paragraph of the documentation. Hi I've been working on some modifications to my printer recently and I'm wondering if it's possible to increase the precision for a command like M106 P3 S0. Feb 2, 2019 · I just have a quick question regarding testing multiple fans. This also increases latency by about 120us. The identical m106 commands in th HI on ly Kossel metal with Duet wifi i installed long time ago 3 rgb led strips where each color was controlled by m106 commands to light up during different stages of the print. Thermostatic control is turned on ; Thermal fan on drivers sensor M308 S2 Y"drivers" A"Drivers" ; configure sensor 2 as temperature warning and overheat flags on the TMC2660 on Duet 2 M950 F2 C"fan2" Q100 ; create fan 2 on pin fan2 and set its frequency Thermostatic control is turned off ;M950 F1 C"fan1" Q500 ; create fan 1 on pin fan1 and set its frequency ;M106 P1 S1 H T45 ; set fan 1 value. In RepRapFirmware 2. x is not plug-and-play. If not, is there another option to control a device via the duet Mar 15, 2023 · Doubtful. If no fan index is given, the print cooling fan is selected. 05 B0. no change. In addition it provides opto-isolated Input and Output connections for some of the GPIO functions to allow easier interfacing with PLC control systems. Just to be clear: if you connect the laser PWM input to the Laser/VFD output on the Duet, and configure a fan using M106 F0 C"out9", then you can control the Hello Duet, I have a ToolChanger with 4x 1LCs and am having issues controlling out1 on two separate tools. Mar 15, 2023 · Current state of config. A quick command in the console saves the day to cap the maximum value. I am testing PrusaSlicer once again. Fan1 defaults to being in thermostatic mode controlled by the temperatures of heaters 1 and 2. To use it as a normal controlled fan, you must first cancel thermostatic mode by sending M106 P1 H-1. RRF3. That's why I added the "I" parameter to M106. Please can you test it with a small GCode file containing M106 commands (with no P parameter). Hello, I updated my Ormerod 2 to Duet WiFi. The firmware is RepRapFirmware-dc42 1. 1. RepRapFirmware for Duets generally provides slots 0 thru 5. Basically an upper bound to the already existi Mar 15, 2023 · I guess I didn't touch that from the configuration tool, so I think it's defined as having fan 1 (Which is the thermostatic controlled fan that keeps the heat from coming up the throat. g? So in the last week, my part cooling fan0 stopped working on my duet 2 wifi. Under manual control with an idle machine, M106 will change the fan speed immediately. Duet Web Control 1. So if you connect them in this way, you don't need any M106 commands in config. This causes the fan to spin for even 1% usage. @dc42 said in Question about M106: The resolution depends on the PWM frequency you have set. I'm using Simplyf3d for my gcode. But they are ignored. g" in 'Control > Console'. 11 (2016-04-14) and I have a 24 V DC Source with DUET 0. Learn how to configure Mosquito Magnum+® for dual heater operation in RepRapFirmware 3. Also try "M106 P0 S0 H-1" send by web control/panel Hi, I have a duet2 wifi with last firmware. 6 in Fisher. It would be nice to have a M106 parameter similar to L that would limit the maximum PWM value for a fan. g Thankyou Edited 1 time (s). Hi, I have a Duet v0. After confirming the operation of the fans, to reset the configuration you can either press the "Reset" button on the Duet, or send M999, or re-run config. Snippet from gcode G92 E0. @dc42 said in Question about M106: @fcwilt said in Question about M106: No extra parameters had to be present for the S1 through S254 values to cause the s I was unable to reproduce that, it worked perfectly for me provided that the only parameters to the M106 command were P and S. 0000 G1 E-6. Even when trying to manually send the M106 S### command it'll respond in binary function. So to turn off fan #3 (M950 F3), use M106 P3 S0. Below is a list of the folders and their purpose. 2k Log in to reply undefined fcwilt @dc42 @dc42 said in Question about M106: On my Duet 3 MB6HC with Ffrmware: RepRapFirmware for Duet 3 MB6HC 3. I tried different duet boards as well. I'd like to turn off the blower during the idle by creating two macros on DWC. Duet WiFi hardware designer and firmware engineer Please do not ask me for Duet support Oct 15, 2020 · On my Duet 3 MB6HC with Ffrmware: RepRapFirmware for Duet 3 MB6HC 3. G-code is sent to the printer and promptly executed by a control board, in the Crane's case, the Duet Maestro. Usage: I was brain dead and discovered 2 hours into a 12 hour print that I really don't want to run my fan as hard as it is to minimize heat rise in the motor. BUT, if you want to limit the maximum fan speed (because say it's a bit too powerful), you can do that by using the "X" parameter in your config. 222 W0. Any ideas? ; Configuration file for Duet WiFi (firmware v There are a number pieces of software used by the RepRapPro Duet-based printers: Arduino IDE (Integrated Development Environment) – used for device drivers, and basic communication (see note and links for downloading later in instructions), The RepRap firmware – this controls the hardware functions of the Duet board, Pronterface – used for communication and control … E. I was wondering, if there is a way to tell Simplyf3d to enable P1 and P2 after the first layer and always ignore P0? Normally Simplyf3d doesn't differenciate between P0-2 and tries to turn on the Using M106 P<currenttool-fan-number> Snnn outside of tfreeN. This board has support for 6 external stepper/servo motor drivers, along with similar outputs and IO as the Duet 3 Mainboard 6HC. 7 do not have adjustable freq Any subsequent M106 with an "S" parameter will override any previous "S" value. Turn on at 50% if Driver temp reaches 45C, increase to full speed gradually as the temp rises to 55C Oct 31, 2022 · Quote I'm having this problem as well. The fan speed applies to the next block added to the planner, so it will not take effect until previous moves in the planner are done. 0+, enhancing performance with single or dual temperature sensors for precise control. g with fan 0 on out9 and a fan defined on out8 with thermostatic control. Execute travel (G1) and then start/stop fan (M106) directly, and don't wait until the travel command finish (G1). Jul 20, 2018 · G-code is frequently used programming language to control machine tools, such as a 3D printer. 01 to M106 P3 S0. I was unable to reproduce that, it worked perfectly for me provided that the only parameters to the M106 command were P and S. I've got a duet board and in my Cura created gcode, the commands are given as M106 S255. I swapped fans, no change. When a print is paused the coordinates are saved to slot 1 automatically, and at the start of a tool change the coordinates are saved to slot 2 automatically. 5 T45:55 C"DrvTemp" ; set fan 2 value and connect to sensor 2. I configured thermostatic control for my chamber heater, but I need to turn on fan when heater is on too, and tu @f-kini said in M106 does not work: Also try "M106 P0 S0 H-1" send by web control/panel due, and any speed changes on fan, everytime on full speed, and the I was unable to reproduce that, it worked perfectly for me provided that the only parameters to the M106 command were P and S. Overview RepRapFirmware 3 is the next generation version of RepRapFirmware for Duet 3, Duet 2 WiFi/Ethernet/Maestro, and some other 32-bit motion control electronics. Any config jedi that can take a quick look at my confg. Thermostatic control is turned on ;M950 F2 C"fan2" Q500 ; create fan 2 on pin fan2 and set its frequency ;M106 P2 H2:3 L0. Also, your Multiple motion systems command Dec 11, 2017 · Assuming you have Duet WiFi or Duet Ethernet, normally you should connect the print fan to Fan0 and the hot end heatsink fan to Fan1. However,these temperatures are not May 12, 2016 · If I try M106 P0 S0 I have no response Also via Duet Web Control the fan slider is active but has no effect I run Firmware Version:1. 0 X0. Check heater functionality Manually controlling heaters This is very strange because there should be no difference in how M106 S255 is handled no matter where the GCose command comes from. Can I get some help to get part cooling fan to work. e. Oct 2, 2023 · Which Duet board? Duet wifi 2 and Duex 5 @Drak said in Part Cooling Fan Setup: What exactly do you mean by this? I meant that i tried moving the fan slider bar on the dashboard and nothing happens Does the fan work if you send M106 P0 S1? No nothing happens, when i plug the fan into always on 5v it turns on though. Jul 3, 2020 · @Phaedrux said in Help with Fan - simple question - M106 and M950 Duex: M106 P5 S1 H-1 Nothing happens. Turn on one of the fans and set its speed. g. I've been upgrading my firmware version to newest release (2. However if I manually enter M106 P0 S255 it turns on the fan and acts as expected. More info on the Start GCode routinesand End GCode routinespages. x, define the fan connector with M950 as a general purpose I/O pin that can be controlled using M42. The Crane runs Reprap firmware, you can find an in-depth list of all supported G-code commands on the Duet3D This page describes how to set up the configuration files for IDEX printers, the same firmware binary also supports Cartesian, Delta, CoreXY and other printers kinematics . 2 does much nicer. Hopefully I don't have to change the config file anymore, so if it acts up again, I'll replace the fan. Aug 17, 2022 · Enter in the End-GCode of the filament that the fan you intended for it is switched on with M106, then with G4 a time how long the End-GCode should pause and then the M107 command to switch the fan off. Duet WiFi hardware designer and firmware engineer Nov 11, 2022 · @Phaedrux m106 works perfectly, except when printing. This feels wrong. M106 S0 should Dec 4, 2021 · M106 P 1 I -1 H -1 A 21 ; disable FA N2 & allocate tool 0 to pi n 21 I was unable to reproduce that, it worked perfectly for me provided that the only parameters to the M106 command were P and S. The identical m106 commands in the gcode are ignored. It is inserting M107 at the top of the output gCode which is disabling the hotend fan. 1 (2020-05-19b2) I get Error: M106 : Fan 2 not found. g? I was unable to reproduce that, it worked perfectly for me provided that the only parameters to the M106 command were P and S. Could you please give me an example of how I can solve my si Duet Hardware and wiring 2 13 1. Fan needs to be limited in an office environment with Hello again. Check heater functionality Manually controlling heaters M1 ; heaters and motors off G4 S360 ; Wait for 6 minutes M106 S0 ; fan off Last reply 0 undefined DADIY I must be the only person that likes the printer to play a little tune when it finishes, like the dishwasher and washing machine Last reply 0 undefined Phaedrux Moderator @deckingman: There is not much point in my posting my start and end The Duet 3 Mainboard 6XD is designed to allow interfacing with the most common external stepper and servo motor drivers using step and direction signals, with support for 6 external drivers. Duet WiFi hardware designer and firmware engineer. It's brand new, but with some of these Chinese parts that might not mean much. Last edit at 05/12/2016 07:23AM by setal2003. I would like some commands to be run in asynchronous mode. Duet WiFi hardware designer and firmware engineer On EXP3HC, EXP1HCL and TOOL1RR boards and also Duet 3 Mini boards used in expansion mode, debouncing is now applied to input pins used for endstops, Z probes and GpIn pins. 0000 F2100 ; layer 2, Z = 0. Note, you must have Tool 0 selected for the print fan mapping toi take effect. 6. I connected the part cooling fan to FAN0 and the Extruder fan to FAN1. Further, M106 S Mar 29, 2022 · Hello, Using Duet wifi application, I tried uploading the gcode file and starting printing. 5 W1 (i. g by sending M98 P"config. 2RC2 Behavior As per Duet3D reference, M107 has been deprecated. g or what that is causing M106 S0 to turn off the wrong fan? Dec 31, 2017 · M106 R2 restores the speed of the "default" fan to the recorded value. 04) But still have the problem. I tested the fan always on, perfect. @ratrig0331 You can use the M106 P parameter to specify the fan index to control. Nov 11, 2022 · @Phaedrux m106 works perfectly, except when printing. So i tested the fan on one of the always on ports, it worked perfectly. When I plug that fan into one of the 'always on' connections, it does turn (correct direction) The Hot end fan (p1) will turn on with m106 P1 s255 i1 (or s1) This is the fans Mar 13, 2021 · According to RRF3 M106: Fan On Parameters Pnnn Fan number (optional, defaults to 0). 20 S1. Jun 20, 2019 · Hello, I need my sliced send M106 Sxx and run the fan P2 (Fan layer) and P1 is the fan and works with the temperature of the Hotend. 8. 2 are defined with thermostatic control (Fan 1 and Fan 2) and one is define Jun 17, 2018 · Request I would love to see the possibility to configure a maximum speed for a non-temperature-controlled fan. Mar 15, 2023 · Lead screw driven printer, powered by Duet 2 Wifi MPCNC powered by Duet 2 Wifi CoreXY printer driven by Duet 3 6HC LowRider CNC powered by Duet 2 Wifi 0 undefined SupraGuy marked this topic as a question 17 Mar 2023, 19:21 undefined SupraGuy has marked this topic as solved 17 Mar 2023, 19:21 Mar 15, 2023 · I seem to be misunderstanding M106 / fan control Using Duet Controllers Lead screw driven printer, powered by Duet 2 Wifi MPCNC powered by Duet 2 Wifi CoreXY printer driven by Duet 3 6HC LowRider CNC powered by Duet 2 Wifi 0 Mar 15, 2023 · Doubtful. 5 and you were relying on Fan 1 being thermostatic by default, you will need to configure it yourself by adding command M106 P1 T45 H1:2:3:4:5:6 to config. Grasping at straws currently the F parameter for M563 is not defined, to let it default to 0. x to RRF 3. 00 I1 C"Top" ; FAN2 Enclosure(Duet) Most 4-wire fans have a minimum operating pulse width, below which they do not spin. I'm not sure where this originates from. @dc42 said in Question about M106: @fcwilt said in Question about M106: No extra parameters had to be present for the S1 through S254 values to cause the s Jan 25, 2019 · @ckigar, if M106 P0 H-1 S1 doesn't get the fan spinning when connected to Fan 0, but the same fan does work on the Fan 1 and Fan 2 outputs when you use P1 and P2 in the M106 command, then the Fan 0 output is faulty and you should ask your supplier to replace the Duet. 15 X1 B0. min 0%, max 50%, scaling on) and then pull the speed slider in DWC all the way to 100% - once RRF would have executed that command the slider would jump back to 50%. g: Lead screw driven printer, powered by Duet 2 Wifi MPCNC powered by Duet 2 Wifi CoreXY printer driven by Duet 3 6HC LowRider CNC powered by Duet 2 Firmware configuration Fan or heater output as a GPIO In RepRapFirmware 3. Configuring fans Firmware settings RepRapFirmware 3. calling "M106 S255" caused my fan to run at 35% while it was running at 100% when I executed "M106 S0". x RepRapFirmware 2x and M106 P2 I1 F25000 H-1 L0. 14 and later display the Duet current microcontroller temperature, and the user will be alerted if stepper drivers are overheating. (In RRF_3 relates to the fan number created by M950, NOT the fan pin num The part cooling fan its always on, also try some M106 commands following the instructions on the here, here and via duet web control interface, any changes. g? This page describes how to set up the configuration files for Cartesian printers, and forms the basis for setting up all printer types. 12a. The fan is 12 v and the jumper is set to 12v. ) config. Basically an upper bound to the already existi M106 P1 C"Extruder" S1 H1 T60 ; set fan 1 name and value. These folders contain all the information the Duet board needs to operate properly. The Duet 2 Wifi and Ethernet are 2nd generation Duet 3D printer electronics. 772 M106 S255 ; tool H0. But when Jan 25, 2019 · @ckigar, if M106 P0 H-1 S1 doesn't get the fan spinning when connected to Fan 0, but the same fan does work on the Fan 1 and Fan 2 outputs when you use P1 and P2 in the M106 command, then the Fan 0 output is faulty and you should ask your supplier to replace the Duet. If I manually enter that the same thing happens. x, on Duet 2 WiFi/Ethernet, FAN1 is set up as a thermostatically-controlled fan by default because it is typically used to control the hot end heatsink fan. I successes in doing this from your UI manually, but not when I'm using my gcode file. (One isn't really a fan, it's a set of LED pucks. trueSo on my current setup I got 3 fans. Depending on the fan you have, you may also have to add a pull-up resistor from 5V to that FAN0 output pin, because the Duet will pull that line to GND at a certain frequency. g file. See full list on 3dprintbeast. Duet WiFi hardware designer and firmware engineer Jan 14, 2021 · Sending M106 P0 S0 does turn the part fan (P0) off and M106 P1 S0 turns the extruder fan (P1) off. 3RC2 Operating system type + version Windows 10 3D printer brand / version + firmware version (if known) Duet Wifi 2 - RepRapFirmware 3. 0 (RTOS) ELECTRONICS: Duet WiFi 1. The Duet 3 Mainboard 6XD is designed to allow interfacing with the most common external stepper and servo motor drivers using step and direction signals, with support for 6 external drivers. It is weird because the fan definitely work as I tested it on the duet fan0 and here it worked perfectly with M950 F0 C"fan0" Q500 M106 P0 S1 H-1 I tried to change the jumper to another one but nothing change On my Duet 3 MB6HC with Ffrmware: RepRapFirmware for Duet 3 MB6HC 3. Duet WiFi hardware designer and firmware engineer @adistr said in Run async commands (G1 -> M106): Hi @dc42 and thank you for the quick response. Jul 26, 2021 · M106 P2 H2:4 L0. Example: you have the fan set to M106 P2 L0 X0. What each G-code command does depends on the firmware type the board is running. Duet WiFi hardware designer and firmware engineer Dec 27, 2020 · Version PrusaSlicer 2. 3 T25:60 ; set fan 2 value. Is M106 not the right command at the dc42-fork? Jun 17, 2018 · Request I would love to see the possibility to configure a maximum speed for a non-temperature-controlled fan. x uses the GPIO concept extensively. However, there is also a limit on the number of open files, which is 20 on Duet 3 and 10 on Duet 2. Duet software engineer 0 undefined RatRig0331 @chrishamm Duet Wifi - Dual X Axis On The WorkHorse 3D Printer - YouTube Hi all, I´m quit new to the Duet and I´m installed a Layer Fan to my Kossel (first time due to only used ABS) I can´t get it work. See User manual: Connecting and configuring fans and GCode M106 for more details. I have a duet 2 wifi with rep rap firmware on it, and the z min endstop wont stop the homing or anything. Whenever I press the endstop manually the light near the z axis goes off, but whenever I home and it hits it it dose not stop. However, the same firmware binary also supports Delta, CoreXY and other printers kinematics. PWM control via m106, no problem. So is there a documentation error, something stupid I am doing in config. When you send M303 to tune the hot end, it will automatically turn on any fans that The Duet 3 Main Board 6XD is a fully featured, high powered controller aimed at machines which require external steppers or servos. So before starting a print, m106 works, after a print ends, it works. 02 or later FIRMWARE_DATE: 2018-06-05b3 When I plug my print cooling fan into P0, it doesn't respond to m106 P0 S255 (or s1). com In RRF 2. The fact that it worked reliably on thermostatic control is what really gets me though. @Phaedrux m106 works perfectly, except when printing. Check heater functionality Manually controlling heaters Okay, so I have 3 fans defined. After discovering the issue with the Hemera motors The power leads of the laser control board attach directly to the fan connector and on the Wanhao it just works, but the Duet it is either 0% or 100%. zltev hnn vtxvu drzbgdu qnllh kbgj yjbyz coaihr jhbcsf jmpy udteo laidd yzqpaa opqz ldat